Motor Tester(MTE)
ASA Housing LED Flood light 50W
UAV Motor and PTZ Motor Test System

MT3000 Series;Subject to low inductance of UAV and PTZ windings;3 test data storage; Built-in PLC digital interface, fast matching with automation lines.

  • Details
  • Sales area
  • Enquiry

Features
1. Complete withstand voltage, insulation, turn-to-turn, resistance, inductance (optional) test for one clamping, and three-phase resistor balance can be calculated and determined.
2. Subject to low inductance of UAV and PTZ windings, the interturn test is improved, more interturn concussion period, smooth waveform.
3. 1000 test files can be built, test data storage.
4. Built-in PLC digital interface, fast matching with automation lines.
 
Applications
 


Order or custom data

Model Withstand voltage Insulation Turn-to-turn Resistance Inductance PLC control
AN8217S Yes Yes Yes Yes Optional Optional
AN8217M Yes Yes - Yes Optional Optional
AN8517 Fixture: custom on demand.


AN8217S/AN8217M Specification
Model AN8217S/AN8217M
Voltage withstand measurement Output voltage Range: (300 ~ 3000) V AC; Step: 10V
Accuracy: ± (2.5%× setting +10V); Distortion: <3%
Output frequency 50Hz/60Hz; Accuracy: ±0.1Hz
Actual capacity ≥90% 
Breakdown current Range: (0.10~20.00) mA 
Accuracy: ± (2.5%× reading +5 words)
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Arc Level- 0 to 9, 0: Arc Off
Insulation measurement Output voltage Range: (200 ~ 1000) V DC; Step: 5V
Accuracy: ± (3%× setting +5V)
Ripple coefficient <5% 
Resistance measurement Range: (1.0 ~ 99.9) MΩ, (100 ~500) MΩ
Accuracy: ± (3%× reading +5 words), ≤200MΩ
± (5%× reading +8 words), >200MΩ
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Turn-to-turn measurement Pulse voltage Range: (300~3000) V; Step: 10V
Accuracy: ± (3%× setting +10V)
Storage capacitance Standard capacitance: 0.022µF
Wavefront time ≤0.5µs
Waveform acquisition Frequency: 5kHz~40MHz, 13-level adjustable. Resolution: 8-bit AD
Storage: 1k bytes. Multiple tests: (1 ~ 10) times continuous
Waveform parameter Area, difference area, range: (0 ~ 99)%
Resolution: 0.1%; Accuracy: ±3.0%
Resistance test Resistance measurement Range: 0.1/2/20/200/2k/20k, unit: Ω
Accuracy: ±(0.3%× reading +3 words) (temperature compensation off)
Temperature measurement Range: (0.0~60.0) ℃; Accuracy: ±0.5℃
Weight 35kg (single machine)
Dimension 440(W)×265(H)×550(D) 
 


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland