Motor Tester(MTE)
ASA Housing LED Flood light 50W
Comprehensive Electric Vehicle Test System

MT3000 Series

  • Details
  • Sales area
  • Enquiry

Features
1. Complete withstand voltage, insulation, turn-to-turn, resistance, inductance (optional) test for one clamping, and three-phase resistor balance can be calculated and determined.
2. For low stator winding resistance, set a four-terminal test clip for accurate and stable resistance measurement.
3. For the same electric vehicle stator winding resistance, add a resistance balance test function to calculate the difference between different windings and then determine whether it is qualified.
4. For different electric vehicle stator terminals, we can prepare tooling to ensure that the tester matches the stator;
5. 1000 test files can be built, test data storage, and export data to U disk.
6. Built-in PLC digital interface, fast matching with automation lines.
 

Applications
 


AN8216S Specification

Model AN8216S 
Voltage withstand measurement Output voltage Range: (300 ~ 3000) V AC; Step: 10V
Accuracy: ± (2.5%× setting +10V); Distortion: <3%
Output frequency 50Hz/60Hz; Accuracy: ±0.1Hz
Actual capacity ≥90% 
Breakdown current Range: (0.10~20.00) mA
Accuracy: ± (2.5%× reading +5 words)
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Arc  Level- 0 to 9, 0: Arc Off
Insulation measurement Output voltage Range: (200 ~ 1000) V DC; Step: 5V
Accuracy: ± (3%× setting +5V)
Ripple coefficient <5% 
Resistance measurement Range: (1.0 ~ 99.9) MΩ, (100 ~500) MΩ
Accuracy: ± (3%× reading +5 words), ≤200MΩ
± (5%× reading +8 words), >200MΩ
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s) 
Turn-to-turn measurement Pulse voltage Range: (500~3000) V; Step: 10V
Accuracy: ± (3%× setting +10V)
Storage capacitance Standard capacitance: 0.022µF
Wavefront time ≤0.5µs 
Waveform acquisition Frequency: 5kHz~40MHz, 13-level adjustable. Resolution: 8-bit AD
Storage: 1k bytes. Multiple tests: (1 ~ 10) times continuous
Waveform parameter Area, difference area, range: (0 ~ 99)%
Resolution: 0.1%; Accuracy: ±3.0%
Resistance test Resistance measurement Range: 0.1/ 2/20/200/2k/20k, unit: Ω
Accuracy: ±(0.3%× reading +3 words) (temperature compensation off)
Temperature measurement Range: (0.0~60.0) ℃; Accuracy: ±0.5℃
Weight   35kg (single machine)
Dimension    440(W)×265(H)×550(D) 

Order or custom data
Model Withstand voltage Insulation Turn-to-turn Resistance Inductance PLC control
AN8216S Yes Yes Yes Yes Optional Optional
AN8516S Fixture: custom on demand.


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland