1. Complete withstand voltage, insulation, turn-to-turn, resistance, inductance (optional) test for one clamping.
2. Subject to low inductance of elevator motor windings, the interturn test is improved, more interturn concussion period, smooth waveform.
3. 1000 test files can be built, test data storage.
4. Multi fixtures to test different types of contacts.
5. Built-in PLC digital interface, fast matching with automation lines.
6. Overcome shortcomings of complex elevator industrial test using a single meter, high application efficiency.
7. Stator: According to the characteristics of the elevator motor, test the three-phase balance of resistance, the three-phase current balance of the stator. The test items include phase voltage, insulation, DC resistance, resistance ratio, turn-to-turn etc.
8. Machine: For the elevator motor started by the inverter, the equipment achieves the accurate test on brake release, brake lock, no-load voltage, no-load current, no-load power, no-load frequency and artificial noise.
 

Applications



AN8224S/AN8224M Specification

Model AN8224S/AN8224M 
Voltage withstand measurement Output voltage Range: (300 ~ 3000) V AC; Step: 10V
Accuracy: ± (2.5%× setting +10V); Distortion: <3%
Output frequency  50Hz/60Hz; Accuracy: ±0.1Hz
Actual capacity ≥90% 
Breakdown current Range: (0.10~100.00) mA
Accuracy: ± (2.5%× reading +5 words)
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Arc Level- 0 to 9, 0: Arc Off
Insulation measurement Output voltage Range: (200 ~ 1000) V DC; Step: 5V
Accuracy: ± (3%× setting +5V)
Ripple coefficient <5% 
Resistance measurement Range: (1.0 ~ 99.9) MΩ, (100 ~500) MΩ
Accuracy: ± (3%× reading +5 words), ≤200MΩ
± (5%× reading +8 words), >200MΩ
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Turn-to-turn measurement Pulse voltage Range: (500~3000) V; Step: 10V
Accuracy: ± (3%× setting +10V)
Storage capacitance Standard capacitance: 0.022µF
Wavefront time ≤0.5µs 
Waveform acquisition Frequency: 5kHz~40MHz, 13-level adjustable. Resolution: 8-bit AD
Storage: 1k bytes. Multiple tests: (1 ~ 10) times continuous
Waveform parameter Area, difference area, range: (0 ~ 99)%
Resolution: 0.1%; Accuracy: ±3.0%
Resistance test Resistance measurement Range: 0.1/ 2/20/200/2k/20k, unit: Ω
Accuracy: ±(0.3%× reading +3 words) (temperature compensation off)
Temperature measurement Range: (0.0~60.0) ℃; Accuracy: ±0.5℃


Order or custom data
Model Withstand voltage Insulation Turn-to-turn Resistance Inductance PLC control
AN8224S/M Yes Yes Yes Yes Optional Optional
AN8524 Fixture: custom on demand.


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland