Motor Tester(MTE)
ASA Housing LED Flood light 50W
Comprehensive Induction Motor Test System

For multi-tap multi-speed motors, dual-station 8-channel test; test data storage; Multi fixtures to test different types of contacts; Built-in PLC digital interface, fast matching with automation lines.

  • Details
  • Sales area
  • Enquiry

Features
1. Complete withstand voltage, insulation, turn-to-turn, resistance, inductance (optional), steering, power, capacitive voltage, PG test for one clamping.
2. For multi-tap multi-speed motors, dual-station 8-channel test.
3. 1000 test files can be built, test data storage.
4. Multi fixtures to test different types of contacts.
5. Built-in PLC digital interface, fast matching with automation lines.
 
Stator (multi-speed stator, pump stator): Test items include withstand voltage, insulation, turn-to-turn, resistance, anti-embedded, magnetic spin, inductance (optional), dual-station 8-channel (single-station 16-channel) integrated test for one clamping.
                                                      
Machine (multi-speed motor): Test items include withstand voltage, insulation, turn-to-turn, resistance, power, stall, LV start, steering, capacitive voltage test. Built-in switching circuit, automatic high/medium/low/micro/super-micro switching.

Applications

 

AN8211S/AN8211M Specification

Model AN8211S/AN8211M  
Voltage withstand measurement Output voltage Range: (300 ~ 3000) V AC; Step: 10V
Accuracy: ± (2.5%× setting +10V); Distortion: <3%
Output frequency 50Hz/60Hz; Accuracy: ±0.1Hz
Actual capacity  ≥90% 
Breakdown current Range: (0.10~20.00) mA, optional 100mA
Accuracy: ± (2.5%× reading +5 words)
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Arc Set to 0, (1.00~10.00) mA, 0: Arc Off
Insulation measurement Output voltage Range: (200 ~ 1000) V DC; Step: 5V
Accuracy: ± (3%× setting +5V)
Ripple coefficient <5% 
Resistance measurement Range: (1.0 ~ 99.9) MΩ, (100 ~500) MΩ
Accuracy: ± (3%× reading +5 words), ≤200MΩ
± (5%× reading +8 words), >200MΩ
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Turn-to-turn measurement
 
Pulse voltage Range: (500~3000) V; Step: 10V
Accuracy: ± (3%× setting +10V)
Storage capacitance Standard capacitance: 0.022µF
Wavefront time ≤0.5µs 
Waveform acquisition  Frequency: 5kHz~40MHz, 13-level adjustable. Resolution: 8-bit AD
Storage: 1k bytes. Multiple tests: (1 ~ 10) times continuous
Waveform parameter Area, difference area, range: (0 ~ 99)%
Resolution: 0.1%; Accuracy: ±3.0%
Resistance test  Resistance measurement Range: 0.1/ 2/20/200/2k/20k, unit: Ω
Accuracy: ±(0.3%× reading +3 words) (temperature compensation off)
Temperature measurement Range: (0.0~60.0) ℃; Accuracy: ±0.5℃
Power measurement LV Start/Power/Stall Voltage range: 20.0~300.0V
Voltage accuracy: ± (0.3% x display +0.2% x range)
Current range: 0.020~2A~20.00A
Current accuracy: ± (0.3% x display +0.2% x range)
Active power range: 1.0~99.9W~6000W
Active power accuracy: ± (0.8% x display +0.2% x range)
Frequency range: 45.0~500.0Hz
Frequency accuracy: ± (0.1% x display)
Magnetic field scanning Anti-embedded/magnetic spin Anti-embedded: Normal /anti-embedded   Magnetic spin: Forward/Reverse/No magnetic field

Order or custom data
Model Withstand voltage Insulation Turn-to-turn Resistance Anti-embedded Power LV start Stall Capacitive voltage Steering Inductance PLC control
AN8211S Yes Yes Yes Yes Yes - - - - Yes Optional Optional
AN8211M Yes Yes Yes Yes - Yes Yes Yes Yes Yes - Optional


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland