Motor Tester(MTE)
ASA Housing LED Flood light 50W
New Energy Vehicle Motor Test System

MT3000 Testing System; up to 16 channels for single machine, and up to 32 channels for machines in parallel; Wide resistance measurement range; Special test fixture for low resistance; Turn-to-turn resistance/capacity voltage division mode.

  • Details
  • Sales area
  • Enquiry

Features
1. Multi-channel, up to 16 channels for single machine, and up to 32 channels for machines in parallel, new energy motor multi-tap, winding voltage and insulation test. Complete all tests one time after clamping.
2. Wide resistance measurement range. Minimum winding resistance of 1 milliohm. Temperature sensor resistance measurement up to 20k (can be restructured to higher resistance 200K).
3. Special test fixture for low resistance. The resistance test sampling rate can be set to ensure the testing accuracy of small resistance windings. For three-phase symmetrical windings, the three-phase resistance balance can be automatically calculated;
4. Turn-to-turn resistance/capacity voltage division mode. Beautiful low impedance winding shock waveform, easy to distinguish;
5. 1000 test files can be built, test data storage;
6. Built-in PLC digital interface, fast matching with automation lines.
 
Stator: phase voltage, phase insulation, resistance (windings resistance, three-phase resistance balance, temperature sensor resistance), inductance, turn-to-turn
Machine: phase voltage, phase insulation, resistance (windings resistance, three-phase resistance balance, temperature sensor resistance), inductance; customized on demand.
 

Applications



AN8215S/AN8215M/AN8315S/AN8315M Specification

Model AN8215S/8315S AN8215M/8315M
 
Voltage 
withstand measurement
Output voltage Range: (300 ~ 3000) V AC; Step: 10V
Accuracy: ± (2.5%× setting +10V); Distortion: <3%
Output frequency 50Hz/60Hz; Accuracy: ±0.1Hz
Actual capacity ≥90%
Breakdown current Range: (0.10~100.00) mA
Accuracy: ± (2.5%× reading +5 words)
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Arc Level- 0 to 9, 0: Arc Off
Insulation measurement Output voltage Range: (200 ~ 1000) V DC; Step: 5V
Accuracy: ± (3%× setting +5V)
Ripple coefficient <5%
Resistance measurement Range: (1.0 ~ 99.9) MΩ, (100 ~500) MΩ 
Accuracy: ± (3%× reading +5 words), ≤200MΩ
± (5%× reading +8 words), >200MΩ
Duration Range: (1~99) s; Accuracy: ± (1%× setting +0.1s)
Turn-to-turn measurement Pulse voltage Range: (500~3000) V; Step: 10V
Accuracy: ± (3%× setting +10V)
Storage capacitance Standard capacitance: 0.022µF
Wavefront time ≤0.5µs
Waveform acquisition AD Frequency: 5kHz~40MHz, 13-level adjustable. Resolution: 8-bit AD
Storage: 1k bytes. Multiple tests: (1 ~ 10) times continuous
Waveform parameter Area, difference area, range: (0 ~ 99)%
Resolution: 0.1%; Accuracy: ±3.0%
Resistance test Resistance measurement Range: 0.1/2/20/200/2k/20k, unit: Ω
Resolution: 0.01Ω
Accuracy: ±(0.3%× reading +3 words) (temperature compensation off)
20kΩ~200kΩNote: Custom. Lower limit range: 1-100mΩ, upper limit range: 20kΩ ~ 200kΩ
Temperature measurement Range: (0.0~60.0) ℃; Accuracy: ±0.5℃
Inductance test Measurement range 0.1mH~9999H -
Resolution 0.001mH -
Measurement frequency 10Hz/20Hz/1kHz/10kHz -
Measurement accuracy %△ -



Order or custom data
Model Phase voltage Phase insulation Turn-to-turn Resistance Inductance Back EMF
AN8215S/AN8325S Yes Yes Yes Yes Optional Optional
AN8215M/AN8315M Yes Yes - Yes Optional Optional
 


 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland