Three Phase Electrical Safety Comprehensive tester

AN9651TH(F), AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  • Details
  • Sales area
  • Enquiry

  THE SAFETY TESTER IS THE GENERIC TERM TO COVER THE 3 OR 8 TESTS OF THE ELECTRICAL SAFETY STANDARDS, FROM THE INTERNATIONAL STANDARDS

  ground bond test (also called bonding test, ground continuity test )

  - insulation test (also called high resistance test, megger test)

  - hipot test to make a high voltage test (also called dielectric strength test, hipot test, hi-pot test, breakdown test or flash test)

  - leakage current measurement (also called line leakage test)

  The final purpose of those tests is to validate that the product under test is safe for the end user, and complies with the quality requirements from the Low Voltage Directive (LVD), applicable to the corresponding standards (IEC335, IEC950, IEC601, IEC1010, IEC598, IEC990, IEC204...)

  APPLICATION

  MANUFACTURER, LABORATORY, HIGH SPEED PRODUCTION, MAINTENANCE, IN ORDER TO COMPLY WITH THE LOW VOLTAGE DIRECTIVE

  

  • IEC 335 household manufacturer (washing machines, coffee machines, fridges, heaters, boilers, …)

  • IEC 204 industrial equipment (compressor, electrical tools, …)

  • IEC 598 lighting industry (street lights, professional lighting, medical lighting, bulbs, …)

  • IEC 601 medical industry (scanners, surgery equipments, X-ray, electrical beds, …)

  • IEC 950 information technology industry (modems, satellite receivers, servers, printers,cash dispensers, …)

  • IEC 1010 measurement, control and laboratories industry (electrical meters, test & measurement equipment, …)

  SPECIFICATION OVERVIEW

  FROM LABORATORY TO PRODUCTION TESTING, OUR RANGE COVERS THE FOLLOWING SPECIFICATIONS

  • ground bond test up to 64A AC with resistance measurement up to 600mΩ

  • insulation test with DC Voltage from 1V up to 1000 VDC (1V steps),500VA AC Hipot capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in optional leakage current test network MD card,meeting requirements of different industrial standards Maximum test current of Ground Bond resistance is up to 64A

  • leakage current measurement in single or three phases, according to all current international standards

  • AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.

  • power measurement and cos φ measurement

  • Satisfy lattest requirements:Follow the production line developing trends of comprehensive,fast,automation and information.Satisfy quality management,5s management and refid management requirements.

  • GPIB, RS232, Ethernet, 0-10V, PLC available

  • ESRS software for quality purposes, traceability and professional reporting

Model

AN9651TH (F)(Three Phase/single phase7 in1)

Ground Bond Test

Empty Load Output Voltage

<12V

Output Current Setting Range

AC3A~30A 50Hz/60Hz,1A/step

Output Current Setting Accuracy

±(2% of setting+0.2A)

Upper Limit of Resistance

3A≤output current≤10A, 10~600mΩ; 10A

Ground Bond Resolution/ Measurement Range/ Accuracy

1mΩ, 10~600mΩ, ±(2% of reading +2mΩ)

Compensation Resistance Measurement Range/Accuracy

0~200mΩ 1mΩ

Test Time Setting Range

0.5~999.9s 0.1s/step

Insulation Resistance Test

Rated Output Load/Current

1VA (1000V/1mA) 1mA

Output Voltage Range/Adjustable

DC:500V/1000V <1% (Empty load to full load)

Output Voltage Ripple

Pure resistance load, 1000V/1mA, <3%

Insulation Resistance Range

1.0~2000MΩ

Insulation Resistance Lower Limit Setting Range/ Resolution

1.0~99.9 MΩ, 0.1MΩ/step, 100~2000 MΩ 1 MΩ/step

Insulation Resistance Accuracy

1~200 MΩ: ±(2% of reading+2counts) , 200~2000 MΩ: ±(5% of reading+5counts)

Ramp-up Time Range/Resolution

0.1~999.9s 0.1s

Delay Judgment Time

0.3~10.0s (Count from ramp-up )

Test Time Setting Range

0.5~999.9s 0.1s/step

AC Hipot Test

Rated Output Load

500VA (AC:5000V/100mA)

Output Voltage Range /Frequency/Adjustable Rate

500~5000V, 50Hz/60Hz, <2%(Empty load to full load)

Output Voltage Setting Range/Accuracy

Cold state AC:500~5000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V)

Leakage Current Preset Alarm

Upper limit: 0.10~99.99mA; Lower limit: 0.00~99.99mA , 0.01mA/step

Compensation Current Setting Range/ Resolution

0.00 ~5.00mA, 0.01mA

Output Initial Voltage Range

(0%~99%) of test voltage, from 0V to initial voltage need 200ms

Leakage Current Measurement Range/Resolution/Accuracy

0.10~99.99 mA, 0.01mA, ±(2% of reading +2counts)

Test Time/Ramp-Up/Ramp-Down

0.5~999.9s, 0.1~999.9s, 0.0~999.9s(After test pass)

DC Hipot Test

Rated Output Load

60VA (AC:6000V/10mA)

Output Voltage Range /Frequency/Adjustable Rate

500~6000V, <2%(Empty load to full load)

Output Voltage Setting Range/Accuracy

Cold state AC:500~6000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V)

Leakage Current Preset Alarm

Upper limit: 50~9999μA; Lower limit: 0~9999μA , 1μA

Compensation Current Setting Range/ Resolution

0 ~5000μA, 1μA

Output Initial Voltage Range

(0~99%) of test voltage, from 0V to initial voltage need 200ms

Leakage Current Measurement Range/Resolution/Accuracy

50~9999μA , 1μA, ±(2% of reading +2counts)

Test Time/Ramp-Up/Ramp-Down

0.5~999.9s, 0.1~999.9s, 0.3~10.0s(Count from ramp-up)

Leakage Current Test

Output Voltage Range

1.06 times of input voltage (output by isolated transformer)

Leakage Current Range/Resolution

Upper limit: 50~9999μA 1μA

Compensation Current Setting Range/ Resolution

0~500μA 1μA

Test Time Range/Resolution

1.0 ~999.9s 0.1s

Leakage Type

dynamic, static

Three Phase Dynamic Mode

A mode: ABC-AB-BC-CA (standard)
B mode: ABC-AB-ABC-BC-ABC-CA (customized)

Output Voltage Measurement Range/Accuracy

AC 50~500.0V 0.1V, ±(0.5% of reading+2counts)

Leakage Current Measurement Range/Accuracy

50~9999μA 1μA
DC~10kHz: ±(2% of reading+5counts) 10kHz~1MHz: ±(5% of reading+5counts)

Leakage Current Accuracy

50.0~2000μA is ±(5% of reading);2000μA or above is ±(2.5% of reading)

Leakage Power

6kVA ,isolated transformer capacity is designed according to the rated voltage 220V

Time Setting Range

1~300s

Measurement Mode

dynamic, static

Power Test

Output Voltage Range

1.00 times of input voltage (output by isolated transformer)

Power Setting Range/Resolution

Upper limit, Single phase:20~6000W Three phase:60~20000W
Lower limit, Single phase:0~6000W Three phase:0~20000W 1W/step

Test Time Range/Resolution

0.5 ~999.9s 0.1s

Voltage Measurement Range and Accuracy

AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts)

Current Measurement Range and Accuracy

AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts)

Active Power Measurement Range and Accuracy

20.0~999.9W; 1.000~9.999kW; 10.00~20.00kW
45~65Hz: ±(0.5% of reading +2counts)

Power Factor Range and Accuracy

0.100~1.000, ±(2% of reading +2counts)

Low Voltage Start Test

Output Voltage Range

0.85 times of input voltage (output by isolated transformer)

Test Time Range/Resolution

0.5 ~999.9s 0.1s

Current Setting Range/Resolution

Upper limit: 0.30 ~30.00A Lower limit: 0.00 ~30.00A0.01A

Voltage Measurement Range and Accuracy

AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts)

Current Measurement Range and Accuracy

AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts)

Display Mode

10.4 Inch, 640×480, TFT LCD display

Isolated Transformer Capacity

Three Phase:20kVA, Single Phase: 6kVA

Over Current Protection

Power, Start, Leakage Current, Phase Current35A, over 5s protection

DUT Type Setting

Single Phase, Three phase Three line, Three phase Four line

Grounding Mode

Load Grounding, Load Floating

DUT Error Processing

Voice and light alarm

Outer Alarm Light

Red alarm light

PLC Output Interface

Each test function have one

Interface Function

RS232, Outer Printer, Remote

Optional Interface

RS485, GPIB, Internet Card, Inner Printer

Remote control Interface

Foot Pedal, three-color alarm light(on-off signal output, PRINTER, 97 COM interface, Mini-Printer function optional)

Test Group

15 groups, 8 steps / group

Buzzer Alarm Voice

Can turn on ,Can cut



 India  Malaysia  Indonesia
 Brazil  Venezuela  Thailand
 Poland  Hungary  Czech Republic
 Bangladesh  Sri Lanka  Vietnam
 Turkey  Egypt  Pakistan
 Korea  Australia  New-Zealand
 Russia  Saudi Arabia  Dubai
 United States  Canada  Mexico
 Nicaragua  Haiti Columbia
 Ecuador  Peru  Uruguay
Argentina  Chile  Italy
Austria  Czech Rep  Belgium
Netherlands United Kingdom Ireland
France Spain Germany
Portugal Finland  

Product:
Country:
Company:
Name:
Phone:
Email:
Message:
 
Products / Products