Description:
Ainuo Leakage current tester is used to measure the electrical work power (or other power) through the insulation or distribution parameters generated has nothing to do with the job of impedance leakage current, the input impedance of the impedance of the model body. Technical Characteristics:
◆Standard configuration figure 4 of this leakage current tester in GB12113, Compliant with MD demand in new standard GB4706.1-2005
◆Inner high speed 32 bits ARM processor
◆Network card and test bandwidth is DC-1MHz
◆Plug MD card, MD can be changed to satisfy other industrial standard
◆Upper and lower limit leakage current preset function, intelligent judgment, voice and light alarm
◆Adopt VFD display, simple operation
◆Remote interface, RS232/485 interface function
◆Smaller size and more beautiful appearance
  • Product Detail
  • Make an inquiry

Technical Parameter

AN9620X

Power Supply

220V±10%,50Hz

Test Input Voltage Range / Accuracy / Frequency

80~300V  AC  ±(2%× reading +0.5V)  50Hz/60Hz

Test Input Current

12A  AC  MAX

Voltage Indication Range/Accuracy

Voltage Range/80~300V ; Accuracy: ±(2% × reading +0.5V)

Over Current Protection

voice and light alarm, load output breakdown

Built-in Human Network

With standard GBT12113, showed in diagram 4; in compliant with the GB4706.1-2005 human network requirement;
Equip with optional standard network card.

Leakage Current Measurement Range

0.010~0.999mA~10.00mA 

Leakage Current Accuracy

10uA-50uA

DC~1MHz  ±(5%× reading+5uA)

50uA-10.00mA

DC~10kHz  ±(3% × reading +2uA)

10k~1MHz  ±(5% × reading +5uA)

Leakage Current Preset Range

0.050~10.00mA

Test Time Range

Single Time Test:1~999s(LLL=continuous);
precision±1%(Setting 1s Measurement only for line N, not transform L)

Interface Function

RS232, Outer Printer, Remote

Dimension (W×H×D) (mm)

320×110×400