The ANRGL(F) Series Regenerative AC Source/Load Unit adopts advanced digital control methods and power conversion technology, with selectable AC/DC output modes, providing precise power input for AC loads, DC loads, and rectifier-type loads, etc.
The product features four-quadrant operation capability, which can significantly save energy consumption and reduce operating costs. It can set waveform switch-on and switch-off angles for testing surge current and output maintenance time. It can also set the rate of change of voltage and frequency to sweep the range of power input specifications for the DUT.
The power supply mode can simulate abnormal instantaneous rise, drop, short circuit, jitter, and other phenomena in the power grid, simulate distortion of the mains power waveform, and also provide accurate and fast measurement of power parameters. The load mode features a full four-quadrant feedback AC electronic load, capable of absorbing full- capacity energy and providing high-efficiency grid feedback to reduce power consumption; multiple load modes are available to meet different test conditions.
The ANRGL(F) Series Regenerative AC Source/Load Unit Integrated Machine adopts advanced SPWM technology with excellent power output quality, widely used in laboratories and production lines in the photovoltaic, new energy vehicle, and other industries.
Advanced SPWM technology, FPGA digital processing technology, and high-power switching power supply technology with high power density.
Multiple output modes, such as AC, DC, and AC+DC.
100% rated power feedback to the grid, and the power supply can operate in all four quadrants.
Realize three-phase and single-phase parallel operation, and the single-phase output after parallel connection can reach the maximum capacity of the whole unit.
Harmonic synthesis function for 2-50 times interharmonics with a synthesis bandwidth of 3,000Hz.
Three programming functions: sequence, pulse, and step, which simulate interference in the actual grid, with a minimum programming step size of 1ms.
Has a 5-inch LCD, which is small in size, light in weight, and 4U in height, meeting the installation requirements of standard cabinets.
Equipped with RS485 and Ethernet communication interfaces as standard, with optional RS232 and GPlB communication interfaces.
Comes with upper computer software, which can import and export arbitrary waveforms and set parameters through the upper computer.
It has functions of constant current/constant resistance/constant active power/constant apparent power/RLC analog circuit load/PQ mode, etc.
The RLC mode supports various linear network models and nonlinear network models, and the PQ mode enables islanding protection characteristic tests;
Load parameters support online adjustment, allowing for the switching of different load characteristics during operation;
The load is set with CF and PF values to simulate various types of loads.

In the conventional mode, the start-stop angles of the waveform can be set to facilitate surge current tests.

The three-phase output waveform can be independently set to select a sine wave, a square wave, a triangular wave, a clipped sine wave, 30 sets of built-in waveforms, and 6 sets of user-defined waveforms.

It has universally programmable settings for each phase of AC voltage, DC voltage, and frequency. Phase, waveform, and time can be independently set according to single-step settings. Trigger phase and loop count can be set, and parameters of three-phase outputs can be separately configured. Any phase abrupt change/crossing test can be achieved. Rich sequence combinations with a high degree of freedom in parameter settings. By setting different combined sequence parameters, high- and low-voltage crossing tests can be completed. Minimum programming setting time is 1ms, capable of completing a 1ms stop test. Each sequence in each phase can independently set one of the 6 waveforms.


It periodically changes the output state, where the power output will cyclically vary between a regular power supply and a pulse voltage. Each phase of AC voltage, DC voltage, frequency, angle, waveform, time, etc., can be independently set.

Step Mode
Also known as staircase mode, where the output voltage gradually increases or decreases according to the set step size from the initial value. Each phase's AC voltage, DC voltage, and frequency can be independently set for the initial value and change amount. Angle, waveform, step count, and step time for each phase can also be set independently.

Harmonic Synthesis
The power supply has a harmonic editing function (2-50 times), and various harmonic components can be added to the standard sine wave. It has 3 sets of percentage harmonic storage groups and 3 sets of amplitude harmonic storage groups that can be quickly called. The fundamental wave voltage, harmonic content, angle, etc., of each phase can be independently set. Under the percentage mode, the content and angle of each harmonic can be set, with a single harmonic up to 30%, no limit on total harmonic content, and no limit on the number of harmonic superimpositions. Under the amplitude mode, specific voltage values can be set for harmonic components without any percentage relationship with the fundamental wave voltage.

Interharmonic Synthesis
The power supply has an interharmonic editing function, allowing the addition of interharmonic components to the standard sine wave. Interharmonic trigger angle, start-stop frequencies, content, and scan time can be set, with an interharmonic frequency range of 16-3,000Hz.

Operation
A 5-inch color capacitive touch screen and knobs can be used to set the voltage and frequency in the conventional mode, with buttons responsible for starting and stopping the conventional mode.

Upper Computer
It is equipped with the standard upper computer software, with a graphical user interface for convenient and efficient operation.

| Product Model | Total Unit Power | Output Phase Number | AC Voltage | Frequency | DC Voltage | Per-phase Current | Dimension (W*H*D mm) |
| ANRGL002S-350(F) | 2kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL003S-350(F) | 3kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL005S-350(F) | 5kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL006S-350(F) | 6kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL010S-350(F) | 10kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 60A | 432*175*755 |
| ANRGL012S-350(F) | 12kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 70A | 432*175*700 |
| ANRGL015S-350(F) | 15kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 120A | 432*175*755 |
| ANRGL020S-350(F) | 20kVA | Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 120A | 432*175*755 |
| ANRGL003A-350(F) | 3kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -636.30 - 636.30V | 35A | 432*175*700 |
| ANRGL006A-350(F) | 6kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL009A-350(F) | 9kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL012A-350(F) | 12kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL015A-350(F) | 15kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL018A-350(F) | 18kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 35A | 432*175*700 |
| ANRGL020A-350(F) | 20kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 60A | 432*175*755 |
| ANRGL025A-350(F) | 25kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 60A | 432*175*755 |
| ANRGL030A-350(F) | 30kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 60A | 432*175*755 |
| ANRGL050B-350(F) | 50kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 120A | 600*1230*1000 |
| ANRGL060B-350(F) | 60kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 120A | 600*1230*1000 |
| ANRGL075B-350(F) | 75kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 180A | 600*1230*1000 |
| ANRGL090B-350(F) | 90kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 180A | 600*1230*1000 |
| ANRGL100B-350(F) | 100kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 240A | 600*1230*1000 |
| ANRGL120B-350(F) | 120kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 240A | 600*1230*1000 |
| ANRGL150B-350(F) | 150kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 300A | 600*1590*1000 |
| ANRGL180B-350(F) | 180kVA | Three-phase & Single-phase | 0 - 350.00V | 30.000 - 200.000Hz | -495.00 - 495.00V | 360A | 600*1590*1000 |
* The above specifications are subject to change without notice.
| Product Model | ANRGL002S-350(F) | ANRGL003S-350(F) | ANRGL005S-350(F) | ANRGL006S-350(F) | ANRGL010S-350(F) | ANRGL012S-350(F) | ANRGL015S-350(F) | ANRGL020S-350(F) | |||
| Power Supply Capacity | 2kVA | 3kVA | 5kVA | 6kVA | 10kVA | 12kVA | 15kVA | 20kVA | |||
| AC Input | Voltage | Line voltage: 342V-480V; 3-phase 3-wire+ PE | |||||||||
| Current (@342V) | 10A Max | 15A Max | 22A Max | 25A Max | 39A Max | 40A Max | 50A Max Dim (W | en6s5ioAnMax D mm) | |||
| Frequency | 47 - 63Hz | ||||||||||
| Power Factor *1 | ≥0.98 | ||||||||||
| AC Output | Phases | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | ||
| Power | 2kVA | 3kVA | 5kVA | 6kVA | 10kVA | 12kVA | 15kVA | 20kVA | |||
| Voltage | Scope | 0.00 - 350.00V | |||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy | 0.1%F.S. | ||||||||||
| Distortion *2 | 0.3%@50/60Hz;1%@30-200Hz | 0.5%@50/60Hz;1%@30-200Hz | |||||||||
| Source Effect *3 | ≤0.02% | ||||||||||
| Load Effect *4 | ≤0.02% | ||||||||||
| Slew Rate | ≤3V/us | ||||||||||
| Dynamic Response Time | <1ms | ||||||||||
| Current/Phase | Effective Value Range | 35A | 35A | 35A | 35A | 60A | 70A | 120A | 120A | ||
Peak Value Range | 105A | 105A | 105A | 105A | 180A | 210A | 360A | 360A | |||
| Frequency | Scope | 30.000 - 200.000Hz | |||||||||
| Resolution | 0.001Hz | ||||||||||
| Accuracy | 0.01% | ||||||||||
| Power | Scope | 2kW | 3kW | 5kW | 6kW | 10kW | 12kW | 15kW | 20kW | ||
| DC Output | Voltage | Scope | -495.00 - 495.00V | ||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy | 0.1%F.S. | ||||||||||
| Current | Scope | 35A | 35A | 35A | 35A | 60A | 70A | 120A | 120A | ||
Measurement Accuracy | Voltage | Scope | AC:350.00V;DC:495.00V | ||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy *5 | 0.1%F.S. | ||||||||||
| Current | Scope | Effective Value | 35A | 35A | 35A | 35A | 60A | 70A | 120A | 120A | |
| Peak Value | 105A | 105A | 105A | 105A | 180A | 210A | 360A | 360A | |||
| Resolution | 0.01A | ||||||||||
| Effective Value Accuracy*6 | 0.2%F.S. | ||||||||||
| Peak Value Accuracy*6 | 0.5%F.S. | ||||||||||
| Power | Scope | 6kVA | 6kVA | 6kVA | 6kVA | 10kVA | 12kVA | 20kVA | 20kVA | ||
| Resolution | 0.01W | ||||||||||
| Accuracy *7 | 0.3%F.S. | ||||||||||
| Function | Display | 5-inch color touch screen LCD | |||||||||
| Waveform Selection | Sine wave, triangular wave, square wave, clipped sine wave, 30 sets of built-in waveforms, and 6 sets of custom waveforms | ||||||||||
| Start-stop Angle | 0-359.9° | ||||||||||
| Knob Function | Knob adjustment available for conventional mode voltage and frequency settings | ||||||||||
Parallel Operation Function*8 | Can achieve parallel operation of multiple units | ||||||||||
| Harmonics | 2nd- to 50th-order harmonics | ||||||||||
Harmonic and Interharmonic Simulation Bandwidth | 3000Hz | ||||||||||
| Sequence Mode | 200 steps with 9,999 loops. Voltage, frequency, and phase angle can be programmatically outputted | ||||||||||
| Pulse Mode | 9,999 loops. Cyclic changes in voltage amplitude, frequency, and angle | ||||||||||
| Step Mode | 9,999 loops. Change the voltage frequency according to the set voltage and frequency step values | ||||||||||
Online Regulation Function | Under the conventional mode, the output voltage and frequency can be adjusted online, and the waveform can be switched online | ||||||||||
Line Drop Compensation | The device has Sense terminals that allow remote sampling compensation | ||||||||||
Communication Interface | RS485 (standard), Ethernet (standard), synchronous signal (standard), RS232 (optional) and GPIB (optional) | ||||||||||
| Remote Control | None | ||||||||||
Working Environment | Temperature | 0 - 40℃ | |||||||||
| Humidity | 30 - 90%RH | ||||||||||
| Efficiency *9 | ≥92% | ||||||||||
| Protection | Input abnormality, bus overvoltage, output overvoltage and undervoltage, output overcurrent, output overload, and module overheating | ||||||||||
| Shape Dimension (W*H*D mm) | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*755 | 432*175*700 | 432*175*755 | 432*175*755 | |||
| The width of 432mm is the standard 19-inch chassis size without handles; with handles, the width is 480mm. The height of 175mm is without feet; with feet, the height is 188mm. The feet are detachable. The depth of 700mm/755mm is the front and rear panel size excluding terminals and protective parts; including terminals, the depth is 779mm/834mm. | |||||||||||
| Weight | ≤25Kg | ≤25Kg | ≤25Kg | ≤25Kg | ≤26Kg | ≤38Kg | ≤38Kg | ≤38Kg | |||
* The above specifications are subject to change without notice.
| Product Model | ANRGL 003A -350(F) | ANRGL 006A -350(F) | ANRGL 009A -350(F) | ANRGL 012A -350(F) | ANRGL 015A -350(F) | ANRGL 018A -350(F) | ANRGL 020A -350(F) | ANRGL 025A -350(F) | ANRGL 030A -350(F) | |||
| Power Supply Capacity | 3kVA | 6kVA | 9kVA | 12kVA | 15kVA | 18kVA | 20kVA | 25kVA | 30kVA | |||
| AC Input | Voltage | Line voltage: 342V-480V; 3-phase 3-wire+ PE | ||||||||||
Current (@342V) | 15A Max | 20A Max | 25A Max | 30A Max | 35A Max | 40A Max | 45A Max | 55A Max | 65A Max | |||
| Frequency | 47 - 63Hz | |||||||||||
Power Factor | ≥0.98 | |||||||||||
| AC Output | Phases | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | 3-phase/ 1-phase | ||
| Power | Total Power | 3kVA | 6kVA | 9kVA | 12kVA | 15kVA | 18kVA | 20kVA | 25kVA | 30kVA | ||
Power Per Phase | 1kVA | 2kVA | 3kVA | 4kVA | 5kVA | 6kVA | 6.66kVA | 8.33kVA | 10kVA | |||
| Voltage | Scope | 0.00 - 350.00V | ||||||||||
| Resolution | 0.01V | |||||||||||
| Accuracy | 0.1%F.S. | |||||||||||
| Distortion | 0.3%@50/60Hz;1%@30-200Hz | 0.5%@50/60Hz;1%@30-200Hz | ||||||||||
| Source Effect | ≤0.02% | |||||||||||
| Load Effect | ≤0.02% | |||||||||||
| Slew Rate | ≤3V/us | |||||||||||
Dynamic Response Time | <1ms | |||||||||||
Current/ Phase | Effective Value Range | Three-phase Mode | 35A | 35A | 35A | 35A | 35A | 35A | 60A | 60A | 60A | |
Effective Value Range | Single- phase Mode | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | 180A | ||
Peak Value Range | Three- phase Mode | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | 180A | ||
Peak Value Range | Single phase Mode | 315A | 315A | 315A | 315A | 315A | 315A | 540A | 540A | 540A | ||
| Frequency | Scope | 30.000 - 200.000Hz | ||||||||||
| Resolution | 0.001Hz | |||||||||||
| Accuracy | 0.01% | |||||||||||
| DC Output | Power | Total Power | 3kW | 6kW | 9kW | 12kW | 15kW | 18kW | 20kW | 25kW | 30kW | |
Power Per Channel | 1kW | 2kW | 3kW | 4kW | 5kW | 6kW | 6.66kW | 8.33kW | 10kW | |||
| Voltage | Scope | -495.00 - 495.00V | ||||||||||
| Resolution | 0.01V | |||||||||||
| Accuracy | 0.1%F.S. | |||||||||||
| Scope | Single Channel | 35A | 35A | 35A | 35A | 35A | 35A | 60A | 60A | 60A | ||
Parallel Connection | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | 180A | |||
Measurement Accuracy | Voltage | Scope | AC: 350.00V; DC: 495.00V | |||||||||
| Resolution | 0.01V | |||||||||||
| Accuracy | 0.1%F.S. | |||||||||||
| Current | Scope | Effective Value | 105A | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | |
Peak Value | 315A | 315A | 315A | 315A | 315A | 315A | 540A | 540A | 540A | |||
| Resolution | 0.01A | |||||||||||
Effective Value Accuracy | 0.2%F.S. | |||||||||||
Peak Value Accuracy | 0.5%F.S. | |||||||||||
| Power | Scope | 18kVA | 18kVA | 18kVA | 18kVA | 18kVA | 18kVA | 30kVA | 30kVA | 30kVA | ||
| Resolution | 0.01W | |||||||||||
| Accuracy | 0.3%F.S. | |||||||||||
| Function | Display | 5-inch color touch screen LCD | ||||||||||
Waveform Selection | Sine wave, triangular wave, square wave, clipped sine wave, 30 sets of built-in waveforms, and 6 sets of custom waveforms | |||||||||||
Start-stop Angle | 0-359.9° | |||||||||||
Knob Function | Knob adjustment available for conventional mode voltage and frequency settings | |||||||||||
Parallel Operation | Can achieve parallel operation of multiple units | |||||||||||
| Harmonics | 2nd- to 50th-order harmonics | |||||||||||
Harmonic and Interharmonic Simulation Bandwidth | 3000Hz | |||||||||||
| Sequence Mode | 200 steps with 9,999 loops. Voltage, frequency, and phase angle can be programmatically outputted | |||||||||||
| Pulse Mode | 9,999 loops. Cyclic changes in voltage amplitude, frequency, and angle | |||||||||||
| Step Mode | 9,999 loops. Change the voltage frequency according to the set voltage and frequency step values | |||||||||||
Online Regulation | Under the conventional mode, the output voltage and frequency can be adjusted online, and the waveform can be switched online | |||||||||||
Line Drop Compensation | The device has Sense terminals that allow remote sampling compensation | |||||||||||
Communication Interface | RS485 (standard), Ethernet (standard), synchronous signal (standard), RS232 (optional) and GPIB (optional) | |||||||||||
Remote Control | None | |||||||||||
Working Environment | Temperature | 0 - 40℃ | ||||||||||
| Humidity | 30 - 90%RH | |||||||||||
| Efficiency | ≥92% | |||||||||||
| Protection | Input abnormality, overvoltage, output overvoltage and undervoltage, output overcurrent, output overload, and module overheating | |||||||||||
Shape Dimension (W*H*D mm) | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*700 | 432*175*755 | 432*175*755 | 432*175*755 | |||
The 432mm width is the standard 19-inch chassis size without handles; with handles, the width is 480mm. The height is 175mm without feet; with feet, it is 188mm. The feet are detachable. The depth of 700mm/755mm is the front and rear panel size, excluding terminals and protective parts; Including terminals, the depth is 779mm/834mm. | ||||||||||||
| Weight | ≤45Kg | ≤45Kg | ≤45Kg | ≤45Kg | ≤45Kg | ≤45Kg | ≤52Kg | ≤52Kg | ≤52Kg | |||
* The above specifications are subject to change without notice.
| Product Model | ANRGL050B -350(F) | ANRGL060B -350(F) | ANRGL075B -350(F) | ANRGL090B -350(F) | ANRGL100B -350(F) | ANRGL120B -350(F) | ANRGL150B -350(F) | ANRGL180B -350(F) | |||
| Power Supply Capacity | 50kVA | 60kVA | 75kVA | 90kVA | 100kVA | 120kVA | 150kVA | 180kVA | |||
| AC Input | Voltage | Line voltage: 342V-480V; 3-phase 3-wire+ PE | |||||||||
| Current (@342V) | 110A Max | 130A Max | 165A Max | 195A Max | 220A Max | 260A Max | 330A Max | 390A Max | |||
| Frequency | 47 - 63Hz | ||||||||||
| Power Factor *1 | ≥0.98 | ||||||||||
| Phases | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | Three-phase & single-phase | |||
| Power | Total Power | 50kVA | 60kVA | 75kVA | 90kVA | 100kVA | 120kVA | 150kVA | 180kVA | ||
Power Per Phase | 16.66kVA | 20kVA | 25kVA | 30kVA | 33.33kVA | 40kVA | 50kVA | 60kVA | |||
| AC Output | Voltage | Scope | 0.00 - 350.00V | ||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy | 0.1%F.S. | ||||||||||
| Distortion *2 | 0.5%@50/60Hz;1%@30-100Hz | ||||||||||
| Source Effect *3 | ≤0.02% | ||||||||||
| Load Effect *4 | ≤0.02% | ||||||||||
| Slew Rate | ≤3V/us | ||||||||||
| Dynamic Response Time | <1ms | ||||||||||
Current/ Phase | Effective Value Range | Three-phase Mode | 120A | 120A | 180A | 180A | 240A | 240A | 300A | 360A | |
| Effective Value Range | Single phase Mode | 360A | 360A | 540A | 540A | 720A | 720A | 900A | 1080A | ||
| Peak Value Range | Three-phase Mode | 360A | 360A | 540A | 540A | 720A | 720A | 900A | 1080A | ||
Peak Value Range | Single-phase Mode | 1080A | 1080A | 1620A | 1620A | 2160A | 2160A | 2700A | 3240A | ||
| Frequency | Scope | 30.000 - 200.000Hz | |||||||||
| Resolution | 0.001Hz | ||||||||||
| Accuracy | 0.01% | ||||||||||
| DC Output | Power | Tota Power | 50kW | 60kW | 75kW | 90kW | 100kW | 120kW | 150kW | 180kW | |
Power Per Channel | 16.66kW | 20kW | 25kW | 30kW | 33.33kW | 40kW | 50kW | 60kW | |||
| Voltage | Scope | -495.00 - 495.00V | |||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy | 0.1%F.S. | ||||||||||
| Scope | Single Channel | 120A | 120A | 180A | 180A | 240A | 240A | 300A | 360A | ||
| Parallel Connection | 360A | 360A | 540A | 540A | 720A | 720A | 900A | 1080A | |||
| Function | Display | 5-inch color touch screen LCD | |||||||||
Waveform Selection | Sine wave, triangular wave, square wave, clipped sine wave, 30 sets of built-in waveforms, and 6 sets of custom waveforms | ||||||||||
Start-stop Angle | 0-359.9° | ||||||||||
| Knob Function | Knob adjustment available for conventional mode voltage and frequency settings | ||||||||||
| Parallel Operation | None | ||||||||||
| Harmonics | 2nd- to 50th-order harmonics | ||||||||||
Harmonic & Interharmonic Simulation Bandwidth | 3000Hz | ||||||||||
| Sequence Mode | 200 steps with 9,999 loops. Voltage, frequency, and phase angle can be programmatically outputted. | ||||||||||
| Pulse Mode | 9,999 loops. Cyclic changes in voltage amplitude, frequency, and angle | ||||||||||
| Step Mode | 9,999 loops. Change the voltage frequency according to the set voltage and frequency step values | ||||||||||
Online Regulation | Under the conventional mode, the output voltage and frequency can be adjusted online, and the waveform can be switched online | ||||||||||
Line Drop Compensation | The device has Sense terminals that allow remote sampling compensation | ||||||||||
Communication Interface | RS485 (standard), Ethernet (standard), synchronous signal (standard), RS232 (optional) and GPIB (optional) | ||||||||||
| Remote Control | None | ||||||||||
Working Environment | Temperature | 0 - 40℃ | |||||||||
| Humidity | 30 - 90%RH | ||||||||||
| Efficiency *9 | ≥92% | ||||||||||
| Protection | Input abnormality, bus overvoltage, output overvoltage and undervoltage, output overcurrent, output overload, and module overheating | ||||||||||
| Shape Dimension(W*H*D mm) | 600*1,230 (the height with casters is 118)*1,000 | 600*1,590 (the height with casters is 118) * 1,000 | |||||||||
| Weight | ≤330Kg | ≤330Kg | ≤380Kg | ≤380Kg | ≤440Kg | ≤440Kg | ≤500Kg | ≤560Kg | |||
* The above specifications are subject to change without notice.
| Product Model | ANRGL 002S-350(F) | ANRGL 003S-350(F) | ANRGL 005S-350(F) | ANRGL 006S-350(F) | ANRGL 010S-350(F) | ANRGL 012S-350(F) | ANRGL 015S-350(F) | ANRGL 020S-350(F) | |||
| Capacity | 2kVA | 2kVA | 5kVA | 6kVA | 10kVA | 12kVA | 15kVA | 20kVA | |||
| Operating Load Input | Voltage Range | 30-350V | |||||||||
| Currentrange(EffectiveValue) | 35A | 35A | 35A | 35A | 60A | 70A | 120A | 120A | |||
| CurrentrangeCurrent(PeakValue) | 105A | 105A | 105A | 105A | 180A | 210A | 360A | 360A | |||
| Frequency Range | 30 - 200Hz | ||||||||||
| CC Constant Current Mode | Current | Setting Range | 0-35A | 0-35A | 0-35A | 0-35A | 0-60A | 0-70A | 0-120A | 0-120A | |
| Resolution | 0.01A | ||||||||||
| SettingAccuracy*5 | 0.1%+0.2%F.S. | ||||||||||
| Crest Factor CF | Scope | 1.414-3.000 | |||||||||
| Resolution | 0.001 | ||||||||||
| Power Factor PF | Scope | 0.1-1.00 | |||||||||
| Resolution | 0.01 | ||||||||||
| CP Constant Active Power Mode | Power | Scope | 0-2kW | 0-3kW | 0-5kW | 0-6kW | 0-10kW | 0-12kW | 0-15kW | 0-20kW | |
| Resolution | 0.01W | ||||||||||
| SettingAccuracy*5 | 0.3%+0.3%F.S. | ||||||||||
| Crest Factor CF | Scope | 1.414-3.000 | |||||||||
| Resolution | 0.001 | ||||||||||
| Power Factor PF | Scope | 0.1-1.00 | |||||||||
| Resolution | 0.01 | ||||||||||
| CS Constant Apparent Power Mode | Power | Scope | 0-2kVA | 0-3kVA | 0-5kVA | 0-6kVA | 0-10kVA | 0-12kVA | 0-15kVA | 0-20kVA | |
| Resolution | 0.01VA | ||||||||||
| SettingAccuracy*5 | 0.3%+0.3%F.S. | ||||||||||
| Crest Factor CF | Scope | 1.414-3.000 | |||||||||
| Resolution | 0.001 | ||||||||||
| Power Factor PF | Scope | 0.1-1.00 | |||||||||
| Resolution | 0.01 | ||||||||||
| CR Constant Resistance Mode | Resistance | Scope | 1Ω-1200Ω | ||||||||
| Resolution | 0.001Ω | ||||||||||
| SettingAccuracy*5 | 0.3%+0.4%F.S.(0.5-150Ω) | ||||||||||
| RLC Mode | Resistance R | Scope | 1Ω-1200Ω | ||||||||
| Resolution | 0.001Ω | ||||||||||
| Inductance L | Scope | 0.01-5000mH | |||||||||
| Resolution | 0.001mH | ||||||||||
| Capacitance C | Scope | 0.001-5000μF | |||||||||
| Resolution | 0.001μF | ||||||||||
| Resistance RL | Scope | 0Ω-1200Ω | |||||||||
| Resolution | 0.001Ω | ||||||||||
| Resistance RC | Scope | 0Ω-1200Ω | |||||||||
| Resolution | 0.001Ω | ||||||||||
| Measurement Accuracy | Voltage | Scope | AC:350.00V | ||||||||
| Resolution | 0.01V | ||||||||||
| Accuracy | 0.1%F.S. | ||||||||||
| Current | Range | RMS Value | 35A | 35A | 35A | 35A | 60A | 70A | 120A | 120A | |
| Peak Value | 105A | 105A | 105A | 105A | 180A | 210A | 360A | 360A | |||
| Resolution | 0.01A | ||||||||||
| RMS Accuracy | 0.1%+0.2%F.S. | ||||||||||
| Peak Accuracy | 0.3%+0.6%F.S. | ||||||||||
| Power | Range | 6kVA | 6kVA | 6kVA | 6kVA | 10kVA | 12kVA | 20kVA | 20kVA | ||
| Resolution | 0.01W | ||||||||||
| Active Power Accuracy | 0.3%+0.3%F.S. | ||||||||||
| ApparentPowerAccuracy | 0.3%+0.3%F.S. | ||||||||||
* The above specifications are subject to change without notice.
| Product Model | ANRGL003A-350(F) | ANRGL006A-350(F) | ANRGL009A-350(F) | ANRGL012A-350(F) | ANRGL015A-350(F) | ANRGL018A-350(F) | ANRGL020A-350(F) | ANRGL025A-350(F) | ANRGL030A-350(F) | |||
| Capacity | 3kVA | 6kVA | 9kVA | 12kVA | 15kVA | 18kVA | 20kVA | 25kVA | 30kVA | |||
| Operating Load Input (Per Phase) | Voltage Range | 0-350V | ||||||||||
Current Range (Effective Value) | 35A | 35A | 35A | 35A | 35A | 35A | 60A | 60A | 60A | |||
Current Range (Peak Value) | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | 180A | |||
| Frequency Range | 30 - 200Hz | |||||||||||
CC Mode (Per Phase) | Current | Settin Range | 0-35A | 0-35A | 0-35A | 0-35A | 0-35A | 0-35A | 0-60A | 0-60A | 0-60A | |
| Resolution | 0.01A | |||||||||||
Setting Accuracy*5 | 0.1%+0.2%F.S. | |||||||||||
Crest Factor | Scope | 1.414-3.000 | ||||||||||
| Resolution | 0.001 | |||||||||||
Power Factor | Scope | 0.1-1.00 | ||||||||||
| Resolution | 0.01 | |||||||||||
CP Mode (Per Phase) | Power | Scope | 0-1kW | 0-2kW | 0-3kW | 0-4kW | 0-5kW | 0-6kW | 0-6.6kW | 0-8.3kW | 0-10kW | |
| Resolution | 0.01W | |||||||||||
Setting Accuracy*5 | 0.3%+0.3%F.S. | |||||||||||
Crest Factor | Scope | 1.414-3.000 | ||||||||||
| Resolution | 0.001 | |||||||||||
Power Factor | Scope | 0.1-1.00 | ||||||||||
| Resolution | 0.01 | |||||||||||
CS Mode (Per Phase) | Power | Scope | 0-1kVA | 0-2kVA | 0-3kVA | 0-4kVA | 0-5kVA | 0-6kVA | 0-6.6kVA | 0-8.3kVA | 0-10kVA | |
| Resolution | 0.01VA | |||||||||||
Setting Accuracy*5 | 0.3%+0.3%F.S. | |||||||||||
Crest Factor CF | Scope | 1.414-3.000 | ||||||||||
| Resolution | 0.001 | |||||||||||
| Power Factor PF | Scope | 0.1-1.00 | ||||||||||
| Resolution | 0.01 | |||||||||||
CR Mode (Per Phase) | Resistance | Scope | 1Ω-1200Ω | |||||||||
| Resolution | 0.001Ω | |||||||||||
Setting Accuracy*5 | 0.3%+0.4%F.S.(0.5-150Ω) | |||||||||||
| RLC Mode (Per Phase) | Resistance R | Scope | 1Ω-1200Ω | |||||||||
| Resolution | 0.001Ω | |||||||||||
| Inductance L | Scope | 0.01-5000mH | ||||||||||
| Resolution | 0.001mH | |||||||||||
| Capacitance C | Scope | 0.001-5000μF | ||||||||||
| Resolution | 0.001μF | |||||||||||
| Resistance RL | Scope | 0Ω-1200Ω | ||||||||||
| Resolution | 0.001Ω | |||||||||||
| Resistance RC | Scope | 0Ω-1200Ω | ||||||||||
| Resolution | 0.001Ω | |||||||||||
Measurement Accuracy (Per Phase) | Voltage | Scope | AC: 350.00V | |||||||||
| Resolution | 0.01V | |||||||||||
| Accuracy | 0.1%F.S. | |||||||||||
| Current | Range | RMS Value | 105A | 105A | 105A | 105A | 105A | 105A | 180A | 180A | 180A | |
| Peak Value | 315A | 315A | 315A | 315A | 315A | 315A | 540A | 540A | 540A | |||
| Resolution | 0.01A | |||||||||||
RMS Accuracy | 0.1%+0.2%F.S. | |||||||||||
Peak Accuracy | 0.3%+0.6%F.S. | |||||||||||
| Power | Range | 18kVA | 18kVA | 18kVA | 18kVA | 18kVA | 18kVA | 30kVA | 30kVA | 30kVA | ||
| Resolution | 0.01W | |||||||||||
Active Power Accuracy | 0.3%+0.3%F.S. | |||||||||||
Apparent Power Accuracy | 0.3%+0.3%F.S. | |||||||||||